Basic Electricity WAEC 2025 Questions And Answers

The West African Examination Council (WAEC) Has Scheduled The WAEC Basic Electricity 2025 Questions And Answers Paper to Kick off on 29th April 2025.

Basic Electricity WAEC 2025 Questions And Answers

BASIC ELECTRICITY
01-10: BABDAABDCC
11-20: CABADCCCDB
21-30: CBADCCDDBB
31-40: BADAABCBCB
41-50: DBABCACACB

COMPLETED

(1a)
Lenz’s Law states that the direction of the induced current in a conductor is such that it opposes the change in magnetic flux that caused it.

(1b)
(PICK ANY TWO)
(i) Controllable Magnetic Strength: The magnetic field strength of an electromagnet can be adjusted by varying the current.
(ii) On/Off Functionality: Electromagnets can be turned on and off, providing flexibility for different applications.
(iii) Stronger Magnetic Field: Electromagnets can produce stronger magnetic fields compared to permanent magnets of the same size.
(iv) Adjustable Shape and Size: The design of electromagnets can be modified easily to suit specific requirements, such as the number of coils or size.
(v) No Loss of Magnetism Over Time: Unlike permanent magnets, electromagnets do not lose their magnetic strength over time unless the current is turned off.

(1c)
Given:
Number of turns (N) = 10
Current (I) = 3A
Length of magnetic path (L) = 25cm
Length to meters (L) = 0.25m
H = (N x I)/(L)
H = (10×3)/(0.25)
H = (30)/(0.25)
H = 120 A/m

(2a)
Impedance (Z) is the total opposition to the flow of alternating current (AC) in a circuit, which combines both resistance (R) and reactance (X).

(2b)
(Draw the diagram)

(2ci)
Given:
Output RMS Voltage Vrms = 220V
Maximum voltage (Vmax) = Vrms x (√2)
Vmax = 220 x (√2)
Vmax = 220 x 1.414
Vmax = 310.88V

(2cii)
Average value (Vavg) = (2/π) x Vmax
Vavg = (2/π) x 310.88
Vavg = 0.636 x 310.88
Vavg = 197.25V

(3a)
10 lamps at 60 watts each → 10×60 = 600W
5 ceiling fans at 74 watts each → 5×74 = 370W
5 air conditioners at 746 watts each → 5×746 = 3730W
1 electric cooker at 2500 watts → 2500 W
Total power = 600 + 370 + 3730 + 2500 = 7200 W = 7.2kw

(3b)
Energy consumed = Power × Time
= 7.2kw × 5hrs = 36 kWh

Meter reading = 36 kWh

(3c)
(i) Overheating of the cable
(ii) Risk of fire
(iii) Voltage drop and reduced performance of the cooker

(5a)
Draw the diagram

Basic Electricity WAEC 2025 Questions And Answers

(5b)
(PICK ANY ONE)
(i) Voltage Step-Up: Increases voltage at the generation end for efficient long-distance transmission (reduces current and power losses).
(ii) Voltage Step-Down: Decreases voltage at the distribution end to safe levels suitable for homes and industries.
(iii) Impedance Matching: Helps in matching impedance between components for maximum power transfer and system efficiency.
(iv) Electrical Isolation: Provides isolation between different parts of the system to enhance safety and system protection.

(6a)
Lightning Arrester:
(i) Diverts lightning surges to earth.
(ii) Protects transformers from high voltage.
(iii) Prevents damage to substation equipment.
(iv) Limits transient overvoltages.
(v) Ensures safety during lightning storms.

(6b)
Circuit Breaker:
(i) Interrupts current during faults.
(ii) Operates automatically or manually.
(iii) Protects equipment from overload.
(iv) Isolates faulted sections.
(v) Ensures system stability.

(6c)
Isolator:
(i) Disconnects parts of the system.
(ii) Used during maintenance.
(iii) Operates only under no load.
(iv) Provides visible isolation.
(v) Enhances safety for workers.

*WAEC BASIC ELECTRICITY*

*NUMBER SEVEN*

(7ai)
(i) Reduces equipment failure: Regular maintenance helps identify and fix potential problems before they cause breakdowns.
(ii) Extends equipment lifespan: Preventive care ensures devices operate efficiently for a longer time.

(7aii)
(i) Worn-out or faulty capacitor, which can prevent the fan from starting or running at proper speed.
(ii) Damaged or loose wiring, which may lead to malfunction or electrical hazards.

(7bi)
Possible Cause of the Fault:
The possible cause is a short circuit or insulation failure in the kettle, causing the metal body to become energized.

(7bii)
Corrective Action:
Disconnect the kettle from power immediately and have it inspected and repaired or replaced by a qualified electrician.

(7biii)
Preventive Measure:
Regular inspection and maintenance of electrical appliances, including checking for worn-out insulation, damaged cords, or faulty grounding, can prevent such faults.

BASIC ELECTRICITY INSTRUCTIONS

SECTION A
ANSWER THREE QUESTIONS ONLY

QUESTION 1
QUESTION 2
QUESTION 3

SECTION B
ANSWER TWO QUESTIONS ONLY

QUESTION 5
QUESTION 6
QUESTION 7

COMPLETED

RECOMMENDED POST

Visual Art WAEC 2025 Questions And Answers

English Language WAEC 2025 Questions And Answers

CRS WAEC 2025 Question And Answers

IRS WAEC 2025 Questions And Answer

IGBO WAEC 2025 Questions And Answers

Hausa WAEC 2025 Questions And Answers

Yoruba WAEC 2025 Questions And Answers

Literature In English WAEC 2025 Questions And Answers

Marketing WAEC 2025 Questions And Answers

Civic Education WAEC 2025 Questions And Answers

Agric Science WAEC 2025 Questions And Answer

Further Mathematics WAEC 2025 Questions And Answers

Book Keeping WAEC 2025 Questions And Answers

Animal Husbandry WAEC 2025 Questions And Answers

Office Practice WAEC 2025 Questions And Answers

Economics WAEC 2025 Questions And Answers

Government WAEC 2025 Questions And Answers

IRS2025 Questions And Answers

Mathematics WAEC 2025 Questions And Answers

Chemistry WAEC 2025 Questions And Answers

Biology WAEC 2025 Questions And Answers

Physics WAEC 2025 Questions And Answers

Leave a Comment